SLA5851S1JAB1C2A1 BỘ ĐIỀU KHIỂN LƯU LƯỢNG BROOKS INSTRMENT VIETNAM
MASS FLOW CONTROLLER
Model: SLA5851S1JAB1C2A1
Nhà sản xuất: Brooks Instrument
Nhà cung cấp: DIGIHU Vietnam
Mô tả
SLA5850 | SLA5851 | SLA5853 | SLA5860 | SLA5861 | SLA5863 | |
Product Type | Mass Flow Controller | Mass Flow Controller | Mass Flow Controller | Mass Flow Meter | Mass Flow Meter | Mass Flow Meter |
Differentiator | Controller
Flow Range |
Controller
Flow Range |
Controller
Flow Range |
Meter
Flow Range |
Meter
Flow Range |
Meter
Flow Range |
Flow Range (Full Scale Capacity) | 0.003 – 50 slpm | 15 – 150 slpm | 100 – 2500 slpm | 0.003 – 50 slpm | 15 – 150 slpm | 100 – 2500 slpm |
Max Pressure | 1500 psi / 103 bar
Optional 4500 psi / 310 bar |
1500 psi / 103 bar | 1000 psi / 70 bar | 1500 psi / 103 bar
Optional: 4500 psi / 310 bar |
1500 psi / 103 bar | 1000 psi / 70 bar |
Accuracy | ±0.6% of SP | ±0.6% of SP | ±0.6% of SP
1100 slpm up to 2500 slpm: ±0.6% of FS |
±0.6% of SP | ±0.6% of SP | ±0.6% of SP
1100 slpm up to 2500 slpm: ±0.6% of FS |
Repeatability | 0.20% S.P. | 0.20% S.P. | 0.20% S.P. | 0.20% S.P. | 0.20% S.P. | 0.20% S.P. |
Response Time | <1 second | <1 second | <3 seconds | <1 second | <1 seconds | <3 seconds |
Multi-Gas & Range Configurability | Standard | Standard | Standard | Standard | Standard | Standard |
Diagnostic Capability | Status Lights – MFC Health , Network Status
Alarms – Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption Diagnostic/Service Port – RS485 via 2.5 mm jack |
Status Lights – MFC Health , Network Status
Alarms – Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption Diagnostic/Service Port – RS485 via 2.5 mm jack |
Status Lights – MFC Health , Network Status
Alarms – Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption Diagnostic/Service Port – RS485 via 2.5 mm jack |
Status Lights – MFC Health , Network Status
Alarms – Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption Diagnostic/Service Port – RS485 via 2.5 mm jack |
Status Lights – MFC Health , Network Status
Alarms – Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption Diagnostic/Service Port – RS485 via 2.5 mm jack |
Status Lights – MFC Health , Network Status
Alarms – Sensor Output, control Valve output, Over Temperature, Power Surge/Sag, Network Interruption Diagnostic/Service Port – RS485 via 2.5 mm jack |
Analog Communication | 0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA | 0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA | 0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA | 0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA | 0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA | 0-5 Vdc, 1-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA |
Digital Communication | DeviceNet™
EtherCAT® EtherNet/IP™ FOUNDATIONTM Fieldbus Profibus® PROFINET RS-485 |
DeviceNet™
EtherCAT® EtherNet/IP™ FOUNDATIONTM Fieldbus Profibus® PROFINET RS-485 |
DeviceNet™
EtherCAT® EtherNet/IP™ FOUNDATIONTM Fieldbus Profibus® PROFINET RS-485 |
DeviceNet™
EtherCAT® EtherNet/IP™ FOUNDATIONTM Fieldbus Profibus® PROFINET RS-485 |
DeviceNet™
EtherCAT® EtherNet/IP™ FOUNDATIONTM Fieldbus Profibus® PROFINET RS-485 |
DeviceNet™
EtherCAT® EtherNet/IP™ FOUNDATIONTM Fieldbus Profibus® PROFINET RS-485 |
Đánh giá